Walk Test (key
2
)
The Walk Test option allows user 1 to test the function of all detection zones without causing an
alarm.As eachzone isactivatedthezonenumberisdisplayedandtheinternalsounders generate
atwo-tonesound.Whenthezoneisdeactivatedthesounderwillstop,butthedisplaywilllatchthe
activated zone.
11
TSD402 User Manual User Options
UNSET
Enter first 3 digits of Passcode then
[
(e.g.,
5 6 7 [
)
USER OPTION -
Press
2
for Walk Test
Walk Test
NONE
Activate each zone in turn.
No Zones Active
CF- 1 2 3 4 5 F T
As each zone is activat ed t he
internal sounder generates a
two-tone sound and the display
latches the activated zone
All zones activated
Press
]
to abandon te st.
UNSET
CF = Circuit Fault
1 = Zone 1 Activated
2 = Zone 2 Activated
3 = Zone 3 Activated
4 = Zone 4 Activated
5 = Zone 5 Activated
F = Final Exit Activated