Menvier Security TS700 Manuel d'instructions Page 27

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 26
Using the plan of the t ypical three bedroom house, the following part-set arrangements are
required by the occupants of the house:
Full Set - All circuits to be armed.
Part-set Group A - Circuits 9 and 10 to be omitted. This is required for no rmal night setting
when everyone is in the house and have re tired t o bed.
Part-set Group B - Circuit 10 to be omitted. This isrequired when the occupant ofbedroom 2
is away for the weekend.
Part-set Group C - Circuits2, 7,8,9 and10to beomitted.Thisis requiredwhen onlyperimeter
protection is r equi red.
Programming proc edure
1. First crea te a table listing the circuits that are required to be Armed (A ) and Omitted (O) for
each part-set group:
Circuit No. Location Group A Group B Group C
01 Front Door A A A
02 Hallway Detector A A O
03 Smoke Detector A A A
04 Garage up and over door A A A
05 Garage door (back) A A A
06 Kit chen Door A A A
07 Dining Room PIR A A O
08 Lo unge PIR A A O
09 Bedroom 2 PIR O A O
10 Bedroom 1 PIR O O O
2. From theabovetable assign cir cuits 01 - 10 as"Armed"or "Omitted" foreach part-set group,
see page 24 for full details.
3. Program the setting mode for each part-set group, see page 20 for full details..
+
The PIR in the hallway (circuit 02) will need the "Access" attribute so that first person that
comes down the stairs will start the entry timer.
Com mercial Part-Set Application Example
This application example demonstrates how to use the "Part- set Codes" to set and unset different
areas w ithin a commercial premises. Using the plan of the buildin g the fo llowing is re quired:
Part-set code A - Thesales manager willbeassigned this passcode toaccessthe sales and
canteen area.
Part-set code B - The workshop manager will be a ssigned this passcode to acces s th e
workshop and canteen area.
Part-set code C - The stores manager will be assigned this passcode to access the stores
and canteen area.
27
TS700 Installation Manual Appendices
Vue de la page 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32

Commentaires sur ces manuels

Pas de commentaire