TECHNICAL BULLETIN
TS790 & TS900 No. 002 /02/95
TS790 / TS900 Software Version 2.2 and all versions prior
Problem
If a keyswitch zone has been programmed to operate Ward B, the Ward B attribute will be
removed after 14 days.
Solution
Either re-program the keyswitch to another Ward or set the `TEST TIME' to 00.
This problem has been corrected by the release of software Version 2.3, which was issued on
the 17/02/95.