Time Switches
The TS790/TS900 has three programmable time
switches. Each time switch can be programmed
with up to three separate on/off times and made
to operate on any day of the week. The time
switches can be assigned to outputs which in turn
can be used to control internal or external lighting
via a relay etc.
42
Engineers Menu 3 TS790 & TS900 Installation Manual
Time Switch A
Select Option :-
Operates on :-
..............
Time Switch A
On-time 1 0000
Time Switch A
is OFF
Time Switch A
Off-time 1 0000
=TimeSwitchA
Enter On-time
e.g. 1700
Enter Off-time
e.g. 0800
Enter days of operation
1=Sunday, 7=Saturday
e.g. 23456
to toggle ON/OFF
1
ENT ENT ENT ENT
A
=TimeSwitchB
B
=TimeSwitchC
C
=On-time1
1
=On-time2
2
=On-time3
3
= Off-time 1
4
= Off-time 2
5
= Off-time 3
6
= 1st operates on
7
= 2nd operates on
8
= 3rd operates on
9
= Switch manually
0
0
Time Switch A
On-time 1 1700
Time Switch A
Off-time 1 0800
Operates on :-
..MoTuWeThFr..
Engineers menu 3
Select Option :-
Time Switches Flowchart
Vue de la page 45