Menvier Security TS510 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Systèmes de contrôle d'accès de sécurité Menvier Security TS510. Menvier Security TS510 Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Contents

SD1+Speech DiallerInstallation Instructions1ADCB237654890ENTESCSD1+SD1+

Page 2

ContentsGetting Started: SD1+ Menu Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Overview . . . .

Page 3 - Tel No 1

Getting Started: SD1+ Menu OptionsAll of the SD1+ menu options are accessed by entering the userpasscode (default 1234). These menu options allow all

Page 4

OverviewConnectionsThe SD1+ is connected between the alarmcontrol panel and the telephone line. Itbehaves like another extension to thetelephone and d

Page 5

Call AbortThe SD1+ can be programmed so that if it isaccidentally triggered, the call can beaborted. Once aborted, the dialler will stopdialling out i

Page 6 - 4 Digit Code

Programming: Initialising The SD1+When you power up the SD1+ for the first time, a factory restart isrequired. This involves shorting out the factory

Page 7

Changing Your Passcode TypeThe SD1+ requires a passcode to be entered to allow access to theprogram menus. This passcode is normally 4 digits (), butc

Page 8 - Last Message Sent(A to Tel 3)

Call RoutingMessages A, B, C or D can be programmed so that they only reportto certain telephone numbers i.e. Message A might report totelephone numbe

Page 9

Viewing The Last Call LogWhen a call is successfully acknowledged, the SD1+ stores theevent in a “Last Call Log”.The log may then be viewed as follows

Page 10

Programming: Telephone NumbersThe SD1+ stores up to four telephone numbers, with a maximum of 24 digits each. Permission fromthe person(s) being calle

Page 11 - 1. Overview

Forcing The SD1+ to Tone / Pulse DialPulse Dialling: This is the older format and is sometimes referred to as Loop Disconnect/LD. ToneDialling: This i

Page 12

1. OverviewConnections: The SD1+ is connected between the alarm control panel and thetelephone line. It behaves like another extension to the telephon

Page 13

Programming a Pause into the Telephone NumberIf the SD1+ is connected to an internal PABX telephone exchange, a prefix digit i.e. 9 is normallyrequire

Page 14 - East Fincham

Programming a Pager NumberWhen dialling a pager SD1+may have to wait before sending the message. To insert a pause enter“” after the pager number. Whe

Page 15 - Clear Numbers

Recording MessagesThe SD1+ can record up to four phrases A, B, C, D and a common phrase 0. These phrases can beup to forty seconds in total. The five

Page 16 - 5 Seconds

Deleting Phrases & Telephone NumbersIf new phrases need to be recorded or new telephone numbers need to be programmed into theunit, the old ones w

Page 17 - Sending A Test Call

Testing the SD1+: Call Acknowledgement ProcedureIf the unit has been triggered or a test call has been sent, you mustensure that the recipient of the

Page 18 - NO REPLY

Sending A Test CallIt is possible to test that each message plays to each telephone number e.g. you may want to testthat “Message A” plays to telephon

Page 19 - Trouble-Shooting Guide

General: Three Way CallingThree Way Calling is a feature that is available from BT Network Services. For the SD1+ to takeadvantage of this facility, t

Page 20 - 1-4 / ENT

Trouble-Shooting GuideProblemThe recipient has acknowledged the callbut the SD1+ continues to dial the second,third or forth number.CauseThe "Cal

Page 21 - 4. PCB Layout

Quick Reference: Dialler Options.Quick Reference: Advanced Options.496499 Issue 16, CODEREADYOUTPUT- ROUTE-ABORT-VIEWLOG-NEWCODE-4READYSD1+????C,TYPE-

Page 22 - 5. SD1+ Connections

2. Installation RequirementsThe SD1+ has been designed to be connected to an intruder alarm control panel orsimilar. The control panel must have an au

Page 23 - SD1+ trigger input and +12V

5. SD1+ ConnectionsBefore any connections are made to the SD1+ remove the power (battery and 240Vmains) from the control panel. Connections are provid

Page 24 - 8. Commissioning and Testing

6. Control Panel ConnectionsThe table below shows the connection details to various control panels.Control Panel TRIG AFireTRIG BPATRIG CAlarmPolarity

Page 25 - 11. Approval

7. BT. Connections1. Connect telephone line using one of the methods shown below:2. Replace the plastic cover over the telephone line connections.8. C

Page 26 - 12. Troubleshooting Guide

9. Option Switch SettingsThe SD1+ may be fitted with a 4-way option bit switch, this allows the SD1+ to beconfigured for different countries and for e

Page 27

12. Troubleshooting GuideProblem The unit will not dial out.Cause Number incorrectly dialledAction Check the telephone number you are calling has been

Page 28

SD1+1ADCB237654890ENTESCSD1+SD1+

Commentaires sur ces manuels

Pas de commentaire