No/Type Description
006
P.A.
Activates when a PA alarm is detected
and deactivates when the alarm is
reset.
007
Fire
ActivateswhenaFirealarmisdetected
and deactivates when the alarm is
reset.
008
System Set
Activates when any ward is set and
deactivates when the system is fully
unset.
009
Code Accepted
Activatesfor10secondsfollowingentry
of any valid passcode.
010
24 Hour
Activates when a 24Hr alarm is
detected and deactivates when the
alarm is reset.
011
Second Alarm
Activates when a different detector
causes an alarm and remains active
for the duration of the “2nd Alarm
Time”. This output is normally used for
an ALARM CONFIRMATION signal.
012
Courtesy Light
Activates during entry and when any
remote keypad isused. The duration of
this output is controlled by the setting
of the “COURTESY DUR” timer.
013
Engr On Site
Activates when the engineers
passcode is entered and deactivates
when a user passcode is entered.
014
Ccts Omitted
Activates when any circuit is omitted
and deactivates when all circuits are
reinstated.
015
Auxiliary
Activates when an Auxiliary alarm is
detected and deactivates when the
alarm is reset.
016
Ward A Armed
Activates when “Ward A”is in exit mode
and when “Ward A” is set. Deactivates
when “Ward A” is unset.
017
Ward B Armed
Activates when “Ward B” is in exit mode
and when “Ward B” is set. Deactivates
when “Ward B” is unset.
018
Ward C Armed
Activateswhen“WardC”isinexitmode
and when “Ward C” is set. Deactivates
when “Ward C” is unset.
019
Ward S Armed
Activates when “WardS” is in exit mode
and when “Ward S” is set. Deactivates
when “Ward S” is unset.
020
Tamper Fault
Activates when a Tamper alarm is
detected and deactivates when the
alarm is reset.
021
Line Fault
Activates when a telephone line fault is
detected and deactivates when the
fault is cleared.
022
Mains Off
Activates when mains power is
removed and deactivates when the
mains power is restored.
No/Type Description
023
Exit / Entry
Activates when the panel is in the exit
or entry mode.
024
Test Fail
Activates when a circuit fails test,
deactivates when reset by the
engineer.
025
First Knock
Activates when a double knock circuit
is activated for the first time.
Deactivates when the circuit is
activated for the second time or when
the system is reset.
026
Comms Failed
Activates for 5 seconds when the
plug-on digicom fails to
communicate.
027
Comms Success
Activates for 5 seconds when the
plug-on digicom communicates
successfully.
028
Comms Active
Activates when the plug-on digicom is
active and deactivates when the
plug-on digicom is inactive.
029
2nd Entry
Activates when the second entry timer
is started and deactivates when the
second entry timer expires.
030
Entry
Activates when the panel is in the entry
mode.
031
Exit
Activates when the panel is in the exit
mode.
032
Ward A Set Fail
Activates when “Ward A” fails to set
and deactivates when the set fail
condition is reset by the user.
033
Ward B Set Fail
Activateswhen“Ward B”failstosetand
deactivates when the set fail condition
is reset by the user.
034
Ward C Set Fail
Activateswhen“Ward B”failstosetand
deactivates when the set fail condition
is reset by the user.
035
Ward S Set Fail
Activateswhen“Ward S”failstosetand
deactivates when the set fail condition
is reset by the user.
036
Ward A Alarm
Activates when a night or final exit
circuit in “Ward A” causes an alarm
(not tamper) and deactivates when
the alarm in “Ward A” is reset.
037
Ward B Alarm
Activates when a night or final exit
circuitin“WardB” causesanalarm(not
tamper) and deactivates when the
alarm in “Ward B” is reset.
038
Ward C Alarm
Activates when a night or final exit
circuit in “Ward C” causes an alarm
(not tamper) and deactivates when
the alarm in “Ward C” is reset.
039
Ward S Alarm
Activates when a circuit in “Ward S”
causes an alarm and deactivates
when the alarm in “Ward S” is reset.
TS900 Installation Manual Engineer's Menu 1