Vue de la page 61
1. Ifaplug-ondigicomisbeingusedprogramthe
digicom channels as shown below, see
“Plug-on Digi Channels”, on page 22. If a
stand-alone digicom is being used program
the digicom outputs as shown below, see
“Digicom/RedCARE Outputs”, on page 22.
Channel No Output Type
3 005 (Alarm)
7 071 (Abort)
8 011 (Second Alarm)
2.
3. Program the “Abort Delay”timertotherequired
time (the default is 180 seconds), see “System
Timers”, on page 27.
4. Program the digicom channels so that they
report the required signals.
Text Editing Keys
When programming any text the keys on the
keypad function as shown below:
Cursor Types
[^] This is the normal text editing cursor. Use
the text editing keys as shown above.
[|] This is the number cursor. Use the
numbered keys 0 - 9 to enter numeric
data.
Common Key Sequences
Character Key Sequence Character Key Sequence
A 1 U 5
B 1A V 5A
C 1AA W 5AA
D 2C X 5AAA
E 2 Y 5AAAA
F 2A Z 5AAAAA
G 2AA : 1CCCCCCC
H 3C ; 1CCCCCC
I 3 < 1CCCCC
J 3A = 1CCCC
K 3AA > 1CCC
L 3AAA ? 1CC
M 4CC @ 1C
N 4C ! 0A
O 4 " 0AA
P 4A # 0AAA
Q 4AA $ 0AAAA
R 4AAA % 0AAAAA
S 5CC & 0AAAAAA
T 5C
+12V
+DC POWER
Digicom
(stand-alone)
0V
0V
3 - Alarm
Alarm (005) - 3
7 - Abort
Abort (071) - 7
8 - Confirmation
SecondAlarm (011) - 8
TS790/TS900
Figure 31 Alarm Abort & Sequential Confirmation
7 8
0
9
1 2 3
3 5 4
A B C
ENT ESC
A E I
O U 0 (zero)
Move cursor left Change case Move cursor right
Accept text Space Abandon text editing
Up the alphabet Change cursor Down the alphabet
Figure 32 Text Editing Keys