View Circuits
Eachdetectioncircuitmaybeviewedtoascertain
its status. The circuit status conditions and
resistance are shown below:
Status Response Normal Min. Max.
Healthy None 2.2 KΩ 54 Ω 4.1KΩ
Active Alarm 6.9 KΩ 4.1 KΩ 54 KΩ
Tamper Tamper ∞ 54 KΩ ∞
Shorted Alarm 0 Ω 0 Ω 53 Ω
Set System Time
The system time is displayed in a 24hr format on
allremote keypads and isalso used to time stamp
events in the system event log.
Set System Date
The system date is displayed in a day/date/month
format on LCD remote keypads. it is also used to
provide date stamps for events in the system log.
Change Passcode
This option allows the engineer to change their
passcode. The default passcode is 1234 but the
installation engineer should change this to their
own personal 4 digit passcode.
View Circuits
Enter CCT No.>--
Font Door
CCT 10 Healthy
Circuit text
Enter circuit No.
e.g. 10
Circuit No. &
status
= Next Circuit
1
ESC
A
= Jump 10 Circuits
B
= Previous Circuit
C
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2 -
ENGR 2 -
01-H
CCT 01-H
10-H
CCT 10-H
View Circuits Flowchart
Set Clock > ----
Set Clock > 1605
New time
Enter time
e.g. 1605
2
ENT
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2 -
ENGR 2 -
----
----
1605
1605
Set System Time Flowchart
Set Date > ----
Set Date > 2804
New date
Enter date
e.g. 2804
Select the day 1 - 7
1=Sunday, 7=Saturday
e.g. 3 for Tuesday
3
ENT
Engineers menu 2
Select Option :-
Today is :-
Su............
Current day
Today is :-
....Tu........
ENT
StarburstLCD
LED
E2 -
ENGR 2 -
----
----
2804
2804
DAY.1
DAY SUN
DAY. 3
DAY TUE
Set System Date Flowchart
Change pass code
New code > ----
Change pass code
New code > 2580
Enter new passcode
e.g. 2580
4
ENT
Engineers menu 2
Select Option :-
StarburstLCD
LED
E2 -
ENGR 2 -
----
----
2580
2580
Change Passcode Flowchart