Connections & Controls (Cont.)
EXT. VOLUME (VR1) - If an extension loudspeaker is connected to the control panel,
the volume of keypad bleeps, chime, entry and exit tones may
be adjusted using this control (clockwise to increase). Alarm
tones are always full volume.
INT. VOLUME (VR2) - This controls the volume of keypad bleeps, chime, entry and exit
tones from the internal loudspeaker (clockwise to increase). The
volume of the speech dialler playback messages are always full
volume.
F/EXIT - This pair of terminals is for connecting to the Final Exit detection
device, normally a set of magnetic contacts on the front door.
The tamper loop should be connected in series with other loops
across the terminals mark AUX TAMPER (see Connection
diagram).
ZONE 1 (Access) - This pair of terminals may be connected to any type of normally
closed detection device. When activated during a set condition,
a full alarm is generated. It is also possible to program the zone
as "Access" this allows the detector to be activated during entry
and exit when setting/unsetting the system. If the zone is
programmed as "Access" and is armed during a part-set (Home)
condition it will start the entry timer if activated. The tamper loop
should be connected in series with other loops across the
terminals mark AUX TAMPER (see Connection Diagram).
ZONE 2 (Access) - As Zone 1.
ZONE 3 (K'SWITCH) - This pair of terminals may be connected to any type of normally
closed detection device. When activated during a set condition,
a full alarm is generated. It is also possible to program the zone
as "Keyswitch" this allows the zone to be connected to an
electrical keyswitch to set and unset the system. The keyswitch
functionality maybe further programmed to either full set (Away)
or part-set (Home) the system. (see Programming). The tamper
loop should be connected in series with other loops across the
terminals mark AUX TAMPER (see Connection Diagram).
ZONE 4 (Fire) - This pair of terminals may be connected to any type of normally
closed detection device. When activated during a set condition,
a full alarm is generated. It is also possible to program the zone
as "Fire" this allows the zone to be connected to any type of
normally closed smoke or heat detector. The tamper loop should
be connected in series with other loops across the terminals mark
AUX TAMPER (see Connection Diagram).