ZONE 5 (PA) - This pair of terminals may be connected to any type of normally
closed detection device. When activated during a set condition,
a full alarm is generated. It is also possible to program the zone
as "PA" this allows the zone to be connected to any type of
normally closed PA buttons. The tamper loop should be
connected in series with other loops across the terminals marked
AUX TAMPER (see Connection Diagram).
AUX 12V +/- - The auxiliary 12V terminals provides permanent 12V @ 300mA
of power for detectors which require a low voltage supply e.g.,
PIR's, Vibration Detectors, Smoke Detectors etc. The output is
protected by a 1 amp fuse (Aux 12V).
L/S -
- A 16 extension loudspeaker may be connected between L/S-
and AUX 12V+ terminals. The loudspeakers will reproduce all
alarm and advisory tones generated by the control panel.
+
If an extension loudspeaker is fitted to the system it
must be sited more than 0.5 metres from the control
panel. The play-back of speech dialler messages are
not reproduced at the extension loudspeaker.
AUX TAMPER - The tamper protection for all devices must be connected in
series then connected to this pair of terminals.
TMP- - This terminal provides the tamper protection to the external
sounder. It should be connected to the negative tamper return
output on the external sounder. If the external sounder is not
required to be tamper protected, this terminal must be linked to
H/O -.
H/O -/+ - The "Hold Off -" and "Hold Off +" terminals provide permanent
12V hold off supply for the external sounder or SAB module. The
output is protected by a 1 amp fuse (Bell Fuse).
STB - - This terminal provides the switched negative strobe trigger output
(max. 500mA). It should be connected to the -ve strobe input on
the external sounder or SAB module.
The strobe output is activated on all types of alarm (Fire, PA and
Alarm), the output will only deactivate when the triggered alarm
is fully reset.
If a zone remains in a fault condition when the system attempts
to set, the strobe output is activated to give the user external
indication that the system has failed to set.
TSD402 Installation Manual System Installation
13