External Sounder
The External Sounder should be mounted as high as possible so that it is visible and out of
reach to potential intruders. A six core cable is required for connection to the sounder, it
should enter directly through the wall and into the sounder via the cable entries in the back
plate. However, if the cable is run over the surface to the sounder then it should be
protected (e.g., the cable may be run in aluminium conduit).
Detection devices
There are several types of detection devices available which are suitable for domestic
installations as follows:
Passive Infra-Red
(PIR)
- A movement detector which detects movement of an intruder
by the change in infra-red body heat. When fitting PIRs, refer to
the installation instructions supplied with the unit.
In general there are two types of PIR "Standard" and "Latching".
Normally the standard type is used where one detector per zone
is fitted. A six core cable is required for connection.
The latching type is used when more than one detector is fitted
to a zone, the latch facility allows the user to identify the triggered
detector by means of the indicator LED on the detector "latching"
on. If latching detectors are used an eight core cable is required
for connection.
Magnetic
Contacts
- Magnetic contacts consist of an electrical switch which is
operated by a magnet. They come in two varieties, the "Flush"
type is designed to be fitted into the top or side of the
door/window. The "Surface" type is designed to fitted to
doors/windows where it is not possible to use flush contacts e.g.
garage doors, UPVC windows etc. Both types of contacts require
a four core cable for connections.
Personal Attack
(PA) Button
- Normally PA buttons are located by the front door or adjacent to
the bed, and preferably out of reach to small children. Pressing the
button at any time will generate a full alarm. After pressing the
button, it must be reset with the key provided and then reset at the
control panel. PA buttons require a four core cable for connections.
Vibration Detectors - Vibration detectors are normally fitted to windows or door frames.
They are triggered when the device senses a shock attack.
Vibration detectors require a six core cable for connections.
Smoke/Heat
Detectors
- 12V Smoke or heat detectors may be connected to the system
to provide additional protection against fire. When activated a
distinctive internal sounder tone is generated and the external
sounder is pulsed. Smoke detectors require a four core cable for
connections.
TSD402 Installation Manual System Planning
7