View Event Log (Cont.)
1 Ensure that the "ENGR. OPTION -" is displayed. Press
2
to select the View Log option.
2 Press the
[
key to move backwards through the Log.
3 When completed, press
]
to abandon the View Log option.
Walk Test (key
3
)
The Walk Test option allows the engineer to test the function of all detection zones without
causing an alarm. As each zone is activated the zone number is displayed and the internal
sounders generate a two-tone sound. When the zone is deactivated the sounder will stop,
but the display will latch the activated zone.
1 Ensure that the "ENGR. OPTION -" is displayed. Press
3
to select the Walk Test option.
2 Activate each zone in turn by opening doors fitted with alarm contacts and walking
in front of movement detectors. The display will show the activated zones (as shown
below).
3 When completed, press
]
to abandon the Walk Test option.
Exit Time (key
4
)
This timer sets the delay between the user initiating the setting procedure and the system
actually setting. This only applies when the system is programmed to set by "Timed Exit"
(see System Options). The timer may be set between 1 and 255 seconds.
1 Ensure that the "ENGR. OPTION -" is displayed. Press
4
to select the Exit Time option.
2 Enter the timer setting using the number keys e.g., to set the Exit Time to 15 seconds,
enter "0 1 5".
3 When completed, press
[
to accept, a two tone acceptance tone will be heard.
NONE
CF- 1 2 3 4 5 F T
Walk Test /
Circuit Fault
Display
Activate each zone
Zone 3
Zone 2
Zone 1
Tamper
Final Exit
Zone 5
Zone 4
TSD402 Installation Manual Programming
23