Pre Power-Up Checks
Before applying any power to the system, give the system one final check to ensure that:
1 The telephone lead is unplugged from the telephone socket.
2 The wiring and connections conforms to the requirements detailed in this manual.
3 All system cables are kept clear of mains supply cables, telephone cables and R.F.
cables. It is recommended that cable ties be used to keep cables separated.
4 Calculate the total system power consumption and ensure that it does not exceed 750mA.
5 Mains supply cables to the system are connected to an un-switched fused spur.
Initial Power-Up
1 Place a small screwdriver blade between the pins on the Control Panel PCB, marked
FACTORY RESTART (located top left corner). This will ensure that the factory default
values are loaded into memory as show below:
Engineer's Passcode - 1 2 3 4
User 1 Passcode - 5 6 7 8
User 2 Passcode - Not programmed
Zone 1 - Night
Zone 2 - Access
Zone 3 - Night
Zone 4 - Night
Zone 5 - Night
Final Exit - Exit
Exit Time - 030 Seconds
Entry Time - 030 Seconds
Bell Duration - 020 Minutes
Remote Reset Number - 004
Bell Output - SAB (-ve Applied)
Setting Mode - Timed Exit
Reset Authority - User Reset
Number of Re-arms - 3
Operation of Key Switch - AWAY Set (Full)
Operation of RST- Output - Switched 12V
Operation of Final Exit in P/Set - Final Exit
HOME Setting - Zone 1 Omitted
Dialler Alarm Options - No Alarms Report
Acknowledgement Option - Cleared by any 1
System Installation TSD402 Installation Manual