TRG - - This terminal provides the switched negative bell trigger output
(max. 500mA). It should be connected to the -ve bell trigger
input on the external sounder or SAB module. The output may be
programmed for SAB or SCB operation:
SAB
When programmed as SAB, the output will switch to 0V on alarm.
SCB
When programmed as SCB, the output provides a 0V hold off,
which is removed on alarm.
RST - - This terminal may be programmed as either:
Detector Reset
This type of output is used to power detectors which latch their
alarm condition (e.g., smoke detectors, vibration detectors
etc.). Power for such detectors must be connected between
AUX 12V+ and RST-. Following a full alarm the power to this
output is momentarily removed when the user/engineer has
reset the system, this will allow the such detectors to "Reset".
Switched 12V
When programmed as "Switched 12V" the output may be
connected to the latch input terminal on latching detectors
(e.g., PIRs etc.). This feature is normally used when more than
one detector is connected to a single zone. It allows the user to
identify the alarm source by latching the indicator LED on the
detector that caused the alarm activation. The latched LED will
clear when the system is reset.
ALM - - This terminal is switched negative (100mA) on alarm and is
removed when the system is reset.
TRIGGER F,P & A - These terminals are the auxiliary Fire, PA and Alarm trigger inputs
for the speech dialler, they may be used to trigger the the unit
independently from that of the control panel. For example, a
smoke detector could be directly connected to input "F", when
activated it would trigger the "Fire" message on the speech
dialler but not cause the control panel to alarm.
A, B & BC - These terminals are for the telephone line connections, they must
be connected to an approved "B.T. Master socket" or "Extension
socket" using the lead provided (see BT Connections).