Connection Diagram
ALM-
RST-
TRG-
STB-
+
-
TMP-
AUX
TAMPER
L/S-
+
-
ZONE5(PA)
H/O
AUX12V
ZONE4(Fire)
ZONE3(K/Sw)
ZONE2(Access)
ZONE1(Access)
FINALEXIT
TSD402
PIR
+12V
0V
TAMPER
ALARM
ToZone1
ToAUX12V-
ToAUX12V+
PIR
+12V
0V
TAMPER
ALARM
ToZone2
ToAUX12V-
ToAUX12V+
ToZone3
ToFINALEXIT
ToZone5(P .A.)
P.A.Button
FlushContact
SurfaceContact
TerminalStrip
(Notsupplied)
ALARM
Supply -
Supply+
ToAUX+12V
ToRST-
ToZONE4
SmokeDetector
TRIGGER-
STROBE-
HOLDOFF+
HOLDOFF-
TAMPERRETURN-
ExternalSounder
=
Note
Any unused Zones must be
linked out.
PIRs and Surface Contacts may
be connected to any zone. This
diagram is only used to
represent a typical installation
example.
If a Keyswitch is fitted, it must
be connected to Zone 3 and
then programmed as
KEYSWITCH.
If a Smoke/Heat Detector is
fitted, it must be connected to
Zone 4 and then programmed
as FIRE.
If a P.A. Button is fitted, it must
be connected to Zone 5 and
then programmed as P.A.
16 Ohm Extension Loud speaker
(cut R37 to reduce volume)
Figure 3 Sample Connection Diagram
TSD402 Installation Manual System Installation
15