Menvier Security TS400 Manuel d'instructions Page 1

Naviguer en ligne ou télécharger Manuel d'instructions pour Systèmes de contrôle d'accès de sécurité Menvier Security TS400. Menvier Security TS400 Programming instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Instructions

TSD402Intruder AlarmControl Panel & Speech DiallerInstallation & ProgrammingInstructions14 567 89HOME0AWAY23UNSETTSD402

Page 2 - Contents

Final ExitThis is the point at which the user leaves and enters the premises (normally the front door).When setting the system the user must leave the

Page 3 - S/1100/3/R/503255

System InstallationControl Panel layoutInstalling the Control Panel+For your safety, installation of the TSD402 must be conducted in the followingsequ

Page 4 - Compatibility with PABXs

b) Pull down the plastic clip at the bottom right hand corner of the PCB and gentlylift the PCB forward.c) Repeat with the plastic clip at the bottom

Page 5 - Overview

Control Panel PCB LayoutConnections & ControlsThe main PCB has the following "Jumper Plugs" (JP), indicator LEDS and terminalconnections

Page 6 - Speech Dialler Operation

Connections & Controls (Cont.)EXT. VOLUME (VR1) - If an extension loudspeaker is connected to the control panel,the volume of keypad bleeps, chime

Page 7 - Specifications

ZONE 5 (PA) - This pair of terminals may be connected to any type of normallyclosed detection device. When activated during a set condition,a full ala

Page 8 - System Planning

Connections & Controls (Cont.)TRG - - This terminal provides the switched negative bell trigger output(max. 500mA). It should be connected to the

Page 9 - Detection devices

Connection DiagramALM-RST-TRG-STB-+-TMP-AUXTAMPERL/S-+-ZONE5(PA)H/OAUX12VZONE4(Fire)ZONE3(K/Sw)ZONE2(Access)ZONE1(Access)FINALEXITTSD402PIR+12V0VTAMPE

Page 10 - Power Supply Considerations

Installing a TS400 Remote keypadUp to four TS400 remote keypads may be connected to the TSD402 control panel. Theremote keypad is supplied with an int

Page 11 - Installing the Control Panel

Telephone Line ConnectionsThere are two methods of connection for the TSD402 to the telephone line. The first is touse the 2 metre lead supplied (reco

Page 12 - Battery Connection

ContentsRegulatory Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1General, Application & Approval . . . .

Page 13 - Connections & Controls

Pre Power-Up ChecksBefore applying any power to the system, give the system one final check to ensure that:1 The telephone lead is unplugged from the

Page 14

Initial Power-Up (Cont.)2 Switch on the 240V mains supply and remove the screwdriver blade. The internalalarm will bleep every 30 seconds the display

Page 15

ProgrammingProgramming MenusThere are two programming menus within the system. The engineer's programming menuand the user programming menu. The

Page 16

Program Zones (key1)The TSD402 zones may be programmed so that they perform different functions. The zonestypes are as follows:Night (N) - Zones 1-5 m

Page 17 - Connection Diagram

Program Zones (Cont.)1 Ensure that the "ENGR. OPTION -" is displayed. Press1to select Program Zones.2 Press keys 1 to 6 to toggle between th

Page 18

View Event Log (Cont.)1 Ensure that the "ENGR. OPTION -" is displayed. Press2to select the View Log option.2 Press the[key to move backwards

Page 19 - Telephone Line Connections

Entry Time (key5)When the entry procedure is initiated, the Entry Timer is started and the display counts downthe remaining time. If a valid user pass

Page 20 - Initial Power-Up

Remote Reset Number (Cont.)The "Remote Reset" code is generated using an algorithm identified by a 3 digit number.Alternative algorithms may

Page 21 - Initial Power-Up (Cont.)

Re-arm Options 1 re-arms (1)When an alarm occurs, the internal and external sounders areoperated for the length of the bell duration. At the end of th

Page 22 - Programming

System Options (Cont.)1 Ensure that the "ENGR. OPTION -" is displayed. Press9to select System Options.2 Press keys 1 to 7 to toggle between

Page 23 - Program Zones (key

Regulatory RequirementsGeneralThe TSD402 control panel must be installed by a electrically competent person. Beforeattempting to install the unit, the

Page 24 - E1- A A S F P A

Returning to the Unset Mode (key])Once all the engineer programming is completed the system can be returned to the unsetmode by pressing the]key. Howe

Page 25 - CF- 1 2 3 4 5 F T

Installation RecordZone Type Location Chime Home1Night / AccessOn / Off Armed / Omitted2Night / AccessOn / Off Armed / Omitted3Night / keyswitchOn / O

Page 26

Key Function Action Options1 Program Zones Press 1-6 to togglezone typesPress]to end1 Zone 12 Zone 23 Zone 34 Zone 45 Zone 56 Final Exit= Night or Acc

Page 27 - System Options (key

ConnectionsConnection terminals on the TSD402 are described as either "Safety Extra-Low Voltage"circuits (S.E.L.V) or "Telecommunicatio

Page 28

OverviewIntroductionThe TSD402 is a 5 zone (+ Final Exit) control panel with an integral Speech Dialler. It is ideallysuited for domestic and small co

Page 29 - E0- F P A - F P A

The TSD402 incorporates a 3 button set facility which simplifies the setting and part-settingof the system for user. When the user wishes to full set

Page 30 - Unsetting the System

repeated with the acknowledgement "bleeps" again. If the callis not acknowledged at the end of the fifth play of the messagethe unit abandon

Page 31 - Installation Record

System PlanningGeneralThe TSD402 is a flexible system, but care must be taken in planning the installation toprovide maximum protection with minimum i

Page 32 - SECURITY

External SounderThe External Sounder should be mounted as high as possible so that it is visible and out ofreach to potential intruders. A six core ca

Commentaires sur ces manuels

Pas de commentaire