Program Zones (Cont.)
1 Ensure that the "ENGR. OPTION -" is displayed. Press
1
to select Program Zones.
2 Press keys 1 to 6 to toggle between the two options for each zone (as Shown Below).
3 When completed, press
[
to accept, a two tone acceptance tone will be heard.
View Event Log (key
2
)
The TSD402 will store up to 64 events within the memory log. When this option is selected
the most recent event is displayed first. Pressing the
[
key takes you backwards through
the Log and pressing the
]
key abandons the View Log option. Table 1 shows event log
descriptions.
Display Description
ACOFF
Mains power removed.
ACON
Mains power restored.
AUPL TA
Auxiliary or panel lid tamper alarm.
BATTFLT
Battery fault (battery reversed or below 10.5V).
CCTAL -
Full alarm from zone 1 - 5 (F = Final Exit when part-set).
CODETA
Code Tamper (4 incorrect passcode entries).
ENTRYTO
Entry timed-out (system not unset after activating F/Exit zone).
FIREAL
Fire Alarm activated.
SETA
AWAY Set.
SETFAIL
System failed to set (zone still active at end of exit time).
SETH
HOME Set.
USER-
User 1 or 2 passcode entered (User 3 = keyswitch).
--------
No Event
Table 1 Log Event Codes and Descriptions
E1- N N N N N E
1 2 3 4 5 6
Press
Key To
Toggle
Zone 1 = Night
Zone 2 = Night
Zone 3 = Night Zone 4 = Night
Zone 5 = Night
F/Exit = Exit
E1- A A S F P A
Zone
Programming
Display
Zone 3 = Keyswitch
Zone 2 = Access
Zone 1 = Access
Final Exit = Access
Zone 5 = P A
Zone 4 = Fire
Programming TSD402 Installation Manual