Program Zones (Cont.)
1 Ensure that the "ENGR. OPTION -" is displayed. Press
1
to select Program Zones.
2 Press keys 1 to 6 to toggle between the two options for each zone (as Shown Below).
3 When completed, press
[
to accept, a two tone acceptance tone will be heard.
View Event Log (key
2
)
The TSD402 will store up to 64 events within the memory log. When this option is selected
the most recent event is displayed first. Pressing the
[
key takes you backwards through
the Log and pressing the
]
key abandons the View Log option. Table 1 shows event log
descriptions.
Display Description
ACOFF
Mains power removed.
ACON
Mains power restored.
AUPL TA
Auxiliary or panel lid tamper alarm.
BATTFLT
Battery fault (battery reversed or below 10.5V).
CCTAL -
Full alarm from zone 1 - 5 (F = Final Exit when part-set).
CODETA
Code Tamper (4 incorrect passcode entries).
ENTRYTO
Entry timed-out (system not unset after activating F/Exit zone).
FIREAL
Fire Alarm activated.
SETA
AWAY Set.
SETFAIL
System failed to set (zone still active at end of exit time).
SETH
HOME Set.
USER-
User 1 or 2 passcode entered (User 3 = keyswitch).
--------
No Event
Table 1 Log Event Codes and Descriptions
E1- N N N N N E
1 2 3 4 5 6
Press
Key To
Toggle
Zone 1 = Night
Zone 2 = Night
Zone 3 = Night Zone 4 = Night
Zone 5 = Night
F/Exit = Exit
E1- A A S F P A
Zone
Programming
Display
Zone 3 = Keyswitch
Zone 2 = Access
Zone 1 = Access
Final Exit = Access
Zone 5 = P A
Zone 4 = Fire
Programming TSD402 Installation Manual